Biemmedue Room Thermostat
€53.00
Diesel / Methane - 144 ÷ 235 kW
Thermostat predisposition
Dimensions - 14000 ÷ 20000 m³/h
Biemmedue Titan high flow rate hot air generator with indirect combustion available in Diesel, LPG and Methane versions are designed with a new heat exchanger which combined with the new high performance fans is able to offer a thermal efficiency of 96%, it is ideal for heating large industrial warehouses.
TITAN 145M | TITAN 185T | TITAN 235T | |
Code | 02AG171 | 02AG182 | 02AG192 |
Power Supply | 230V | 400V | 400V |
Nominal power | 144.72 kW | 185.54 kW | 235.72 kW |
Air Flow | 14000 m³/h | 16000 m³/h | 20000 m³/h |
Thermostat | Thermostat predisposition | Thermostat predisposition | Thermostat predisposition |
Fuel | Diesel / methane | Diesel / methane | Diesel / methane |
Diesel consumption | 11.45 Kg/h | 14,68 Kg/h | 18.65 Kg/h |
Natural gas consumption G20 | 13.855 m³/h | 17.682 m³/h | 22.035 m³/h |
LPG consumption G31 | 10,57 Kg/h | 13,63 Kg/h | 16.92 Kg/h |
Supply Pressure G20 | 20 mbar | 20 mbar | 20 mbar |
Supply Pressure G31 | 37mbar | 37mbar | 37mbar |
Power Output | 138.93 kW | 178.12 kW | 227.47 kW |
Yield | 96% | 96% | 96.5% |
Static pressure | 300Pa | 500Pa | 500Pa |
Thermal jump at 20°C | 42°C | 46°C | 47°C |
Effective working range | 56 m | 63 m | 70 m |
Electricity consumption | 3.1 kW | 4.2 kW | 4.9 kW |
fireplace Ø | 200mm | 200mm | 200mm |
Ø 1-way air outlet sheath | Ø 600 mm for 50 m max | Ø 700 mm for 50 m max | Ø 700 mm for 50 m max |
Ø 2-way air outlet sheath | Ø 500 mm for 30 m max | Ø 500 mm for 30 m max | Ø 600 mm for 30 m max |
Ø 4-way air outlet sheath | Ø 350 mm for 25 m max | Ø 350 mm for 25 m max | Ø 400 mm for 25 m max |
Ø snorkel sheath | Ø 100 mm for 6 m max | Ø 100 mm for 6 m max | Ø 150 mm for 6 m max |
Ø air intake sheath | Ø 650 mm for 10 m max | Ø 720 mm for 10 m max | Ø 750 mm for 10 m max |
Dimension | 219 x 90 x 151cm | 241 x 92 x 162cm | 263 x 104 x 184cm |
Weight | 361 Kg | 430 kgs | 535 kgs |
TITAN 145M | TITAN 185T | TITAN 235T | |
Code | 02AG171 | 02AG182 | 02AG192 |
Power Supply | 230V | 400V | 400V |
Nominal power | 144.72 kW | 185.54 kW | 235.72 kW |
Air Flow | 14000 m³/h | 16000 m³/h | 20000 m³/h |
Thermostat | Thermostat predisposition | Thermostat predisposition | Thermostat predisposition |
Fuel | Diesel / methane | Diesel / methane | Diesel / methane |
Diesel consumption | 11.45 Kg/h | 14,68 Kg/h | 18.65 Kg/h |
Natural gas consumption G20 | 13.855 m³/h | 17.682 m³/h | 22.035 m³/h |
LPG consumption G31 | 10,57 Kg/h | 13,63 Kg/h | 16.92 Kg/h |
Supply Pressure G20 | 20 mbar | 20 mbar | 20 mbar |
Supply Pressure G31 | 37mbar | 37mbar | 37mbar |
Power Output | 138.93 kW | 178.12 kW | 227.47 kW |
Yield | 96% | 96% | 96.5% |
Static pressure | 300Pa | 500Pa | 500Pa |
Thermal jump at 20°C | 42°C | 46°C | 47°C |
Effective working range | 56 m | 63 m | 70 m |
Electricity consumption | 3.1 kW | 4.2 kW | 4.9 kW |
fireplace Ø | 200mm | 200mm | 200mm |
Ø 1-way air outlet sheath | Ø 600 mm for 50 m max | Ø 700 mm for 50 m max | Ø 700 mm for 50 m max |
Ø 2-way air outlet sheath | Ø 500 mm for 30 m max | Ø 500 mm for 30 m max | Ø 600 mm for 30 m max |
Ø 4-way air outlet sheath | Ø 350 mm for 25 m max | Ø 350 mm for 25 m max | Ø 400 mm for 25 m max |
Ø snorkel sheath | Ø 100 mm for 6 m max | Ø 100 mm for 6 m max | Ø 150 mm for 6 m max |
Ø air intake sheath | Ø 650 mm for 10 m max | Ø 720 mm for 10 m max | Ø 750 mm for 10 m max |
Dimension | 219 x 90 x 151cm | 241 x 92 x 162cm | 263 x 104 x 184cm |
Weight | 361 Kg | 430 kgs | 535 kgs |
On Request Accessories
Tutti gli Accessori