![Biemmedue FARM - Riscaldatori per Serre Agricole Biemmedue FARM - Riscaldatori per Serre Agricole](https://indors.eu/8204-large_default/biemmedue-farm-heaters-for-agricultural-greenhouses.jpg)
![Termostato per generatore aria calda a Gas MASTER DESA accensione elettronica](https://indors.eu/7392-home_default/thermostat-for-hot-air-generator-biemmedue.jpg)
LPG - 85 ÷ 236 kW
Predisposition for thermostat
98 x 91 x 74 cm - 7000 ÷ 16200 m³ / h
Biemmedue FARM heater for agricultural greenhouses with high capacity designed to adapt to all circumstances, it can be installed both in vertical and horizontal position, on the floor, with wheels kit or suspended and can be used with Diesel, LPG or Methane with single-phase or three-phase power supply .
In addition to adapting the heater to any situation, special attention was paid to the performance and safety of the heater.
In fact, thanks to the new heat exchanger combined with the new higher performance fans, it allows to obtain a thermal efficiency of 92 ÷ 93% while the 3 thermostats it is equipped with guarantee 100% safety.
High quality of components guaranteed by Biemmedue, leader in the design and production of industrial hot air generators.
Farm 85 | Farm 110 | Farm 145 | Farm 185 | Farm 235 | |
Power Supply | 230V | 230V | 230V or 400V | 230V or 400V | 230V or 400V |
Nominal power | 85.62 kW | 110.46 kW | 144.72 kW | 185.54 kW | 235.72 kW |
Electric power | 670 W | 1190 W | 1570 W | 1550 W | 2550W |
Power Yield | 79.37 kW | 102.51 kW | 134.87 kW | 171.07 kW | 216.86 kW |
Thermostat | Predisposition for thermostat | Predisposition for thermostat | Predisposition for thermostat | Predisposition for thermostat | Predisposition for thermostat |
Air flow | 7000 m³ / h | 8500 m³ / h | 11000 m³ / h | 12000 m³ / h | 16200 m³ / h |
Fuel | Diesel / Methane | Diesel / Methane | Diesel / Methane | Diesel / Methane | Diesel / Methane |
Diesel consumption | 6.77 Kg / h | 8.74 Kg / h | 11.45 Kg / h | 14.68 Kg / h | 18.65 Kg / h |
Methane consumption | 7.935 m³ / h | 10.433 m³ / h | 13,664 m³ / h | 17,383 m³ / h | 22,095 m³ / h |
Thermal efficiency | 92.7% | 92.8% | 93.2% | 92.2% | ninety two% |
Static Pressure Avail. | 200 Pa | 200 Pa | 200 Pa | 200 Pa | 200 Pa |
Thermal jump at 20 ° C | 48 ° C | 52 ° C | 52 ° C | 61 ° C | 58 ° C |
Effective working range | 45 m | 43 m | 43 m | 51 m | 55 m |
Supply pressure G20 | 20 mbar | 20 mbar | 20 mbar | 20 mbar | 20 mbar |
LPG consumption G31 | 3.127 m³ / h | 4.191 m³ / h | 5,436 m³ / h | 6.976 m³ / h | 8.819 m³ / h |
Supply pressure G31 | 37 mbar | 37 mbar | 37 mbar | 37 mbar | 37 mbar |
Ø Chimney | 150 mm | 150 mm | 200 mm | 200 mm | 200 mm |
Ø 1 WAY air outlet sheath | 500 mm for Max 100 m | 500 mm for Max 100 m | 600 mm for Max 100 m | 700 mm for Max 100 m | 700 mm for Max 100 m |
Ø 2 WAY air outlet sheath | 400 mm for Max 50 m | 400 mm for Max 50 m | 500 mm for Max 50 m | 500 mm for Max 50 m | 500 mm for Max 50 m |
Ø snorkel sheath | 100 mm for Max 5 m | 100 mm for Max 5 m | 100 mm for Max 5 m | 100 mm for Max 5 m | 100 mm for Max 5 m |
Ø resumed sheath | 510 mm for Max 6 m | 570 mm for Max 6 m | 650 mm for Max 6 m | 650 mm for Max 6 m | 720 mm for Max 6 m |
Dimension | 98 x 91 x 74 cm | 111 x 95 x 77 cm | 122 x 108 x 838 cm | 132 x 114 x 86 cm | 151 x 131 x 94 cm |
Weight | 99 Kg | 122 Kg | 158 Kg | 163 Kg | 233 Kg |
Farm 85 | Farm 110 | Farm 145 | Farm 185 | Farm 235 | |
Power Supply | 230V | 230V | 230V or 400V | 230V or 400V | 230V or 400V |
Nominal power | 85.62 kW | 110.46 kW | 144.72 kW | 185.54 kW | 235.72 kW |
Electric power | 670 W | 1190 W | 1570 W | 1550 W | 2550W |
Power Yield | 79.37 kW | 102.51 kW | 134.87 kW | 171.07 kW | 216.86 kW |
Thermostat | Predisposition for thermostat | Predisposition for thermostat | Predisposition for thermostat | Predisposition for thermostat | Predisposition for thermostat |
Air flow | 7000 m³ / h | 8500 m³ / h | 11000 m³ / h | 12000 m³ / h | 16200 m³ / h |
Fuel | Diesel / Methane | Diesel / Methane | Diesel / Methane | Diesel / Methane | Diesel / Methane |
Diesel consumption | 6.77 Kg / h | 8.74 Kg / h | 11.45 Kg / h | 14.68 Kg / h | 18.65 Kg / h |
Methane consumption | 7.935 m³ / h | 10.433 m³ / h | 13,664 m³ / h | 17,383 m³ / h | 22,095 m³ / h |
Thermal efficiency | 92.7% | 92.8% | 93.2% | 92.2% | ninety two% |
Static Pressure Avail. | 200 Pa | 200 Pa | 200 Pa | 200 Pa | 200 Pa |
Thermal jump at 20 ° C | 48 ° C | 52 ° C | 52 ° C | 61 ° C | 58 ° C |
Effective working range | 45 m | 43 m | 43 m | 51 m | 55 m |
Supply pressure G20 | 20 mbar | 20 mbar | 20 mbar | 20 mbar | 20 mbar |
LPG consumption G31 | 3.127 m³ / h | 4.191 m³ / h | 5,436 m³ / h | 6.976 m³ / h | 8.819 m³ / h |
Supply pressure G31 | 37 mbar | 37 mbar | 37 mbar | 37 mbar | 37 mbar |
Ø Chimney | 150 mm | 150 mm | 200 mm | 200 mm | 200 mm |
Ø 1 WAY air outlet sheath | 500 mm for Max 100 m | 500 mm for Max 100 m | 600 mm for Max 100 m | 700 mm for Max 100 m | 700 mm for Max 100 m |
Ø 2 WAY air outlet sheath | 400 mm for Max 50 m | 400 mm for Max 50 m | 500 mm for Max 50 m | 500 mm for Max 50 m | 500 mm for Max 50 m |
Ø snorkel sheath | 100 mm for Max 5 m | 100 mm for Max 5 m | 100 mm for Max 5 m | 100 mm for Max 5 m | 100 mm for Max 5 m |
Ø resumed sheath | 510 mm for Max 6 m | 570 mm for Max 6 m | 650 mm for Max 6 m | 650 mm for Max 6 m | 720 mm for Max 6 m |
Dimension | 98 x 91 x 74 cm | 111 x 95 x 77 cm | 122 x 108 x 838 cm | 132 x 114 x 86 cm | 151 x 131 x 94 cm |
Weight | 99 Kg | 122 Kg | 158 Kg | 163 Kg | 233 Kg |
Our workshop is able to guarantee efficient and professional repairs: speed; of intervention, competence and availability are our strengths.
By purchasing from Indors you will also have purchased peace of mind: our Assistance and Repairs Service guarantees quick and timely solutions for any problem thanks to the safe availability; of spare parts, your equipment will always be efficient and available within a few days at a low cost. More information
All products sold by Indors are covered by a legal guarantee of 2 years from the date of purchase for purchases by individuals (12 months for professional users) for lack of conformity, pursuant to art. 128 ff. Legislative Decree no. 206/2005.
More information
On Request Accessories
Tutti gli Accessori